Type TC-ER 600 Volt Power Cable M-4
Type TC-ER Power Cable M-4
Alan Wire Type TC-ER Control Cable is intended for use in accordance with Article 336 of ANSI/NFPA 70 National Electrical Code. Suitable for use in wire ways, trays, channels, conduit, ducts, and Class I Division II Hazardous Locations. It is UL listed for direct burial in wet or dry locations, or in areas exposed to chemicals or oils. Sunlight resistant and available as exposed run (ER) for use between cable trays and utilization equipment and Joist Pull Applications in accordance with NEC 336.10 (7).
Standards & Specifications
- 8 AWG Thru 500 MCM Soft-Annealed, Bare Copper per ASTM B3 & ASTM-B787
- UL 83
- Flame-Retardant Insulation
- PVC Rated 90°C Dry/75°C Wet
- Color Coded per Method ICEA Method M4 with Printed Numbers
- Finished Cable Meets Specification UL 1277
- ARRA 2009 Section 1605 “Buy American” Compliant
- Constructed with Nylon Rip-Cord
Wire Size & Specs
Conductor | |||||
---|---|---|---|---|---|
Size (AWG) | Number of Conductors |
Ground Size | Nominal Jacket Thickness(Inches) |
Nominal O.D (Inches) |
Approx Net WT./MFT |
Conductor Size (AWG) 8 |
Number of Conductors 3 | Ground Size 10 | Nominal Jacket Thickness(Inches) 0.060 |
Nominal O.D (Inches) 0.570 |
Approx Net WT./MFT 288 |
Conductor Size (AWG) 8 |
Number of Conductors 4 | Ground Size 10 | Nominal Jacket Thickness(Inches) 0.060 |
Nominal O.D (Inches) 0.660 |
Approx Net WT./MFT 385 |
Conductor Size (AWG) 6 |
Number of Conductors 3 | Ground Size 8 | Nominal Jacket Thickness(Inches) 0.060 |
Nominal O.D (Inches) 0.610 |
Approx Net WT./MFT 415 |
Conductor Size (AWG) 6 |
Number of Conductors 4 | Ground Size 8 | Nominal Jacket Thickness(Inches) 0.060 |
Nominal O.D (Inches) 0.670 |
Approx Net WT./MFT 549 |
Conductor Size (AWG) 4 |
Number of Conductors 3 | Ground Size 8 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 0.780 |
Approx Net WT./MFT 650 |
Conductor Size (AWG) 4 |
Number of Conductors 4 | Ground Size 8 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 0.950 |
Approx Net WT./MFT 806 |
Conductor Size (AWG) 2 |
Number of Conductors 3 | Ground Size 6 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 0.910 |
Approx Net WT./MFT 957 |
Conductor Size (AWG) 2 |
Number of Conductors 4 | Ground Size 6 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.050 |
Approx Net WT./MFT 1195 |
Conductor Size (AWG) 1 |
Number of Conductors 3 | Ground Size 6 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.210 |
Approx Net WT./MFT 1395 |
Conductor Size (AWG) 1/0 |
Number of Conductors 3 | Ground Size 6 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.280 |
Approx Net WT./MFT 1447 |
Conductor Size (AWG) 2/0 |
Number of Conductors 3 | Ground Size 6 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.350 |
Approx Net WT./MFT 1737 |
Conductor Size (AWG) 3/0 |
Number of Conductors 3 | Ground Size 4 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.410 |
Approx Net WT./MFT 2200 |
Conductor Size (AWG) 4/0 |
Number of Conductors 3 | Ground Size 4 | Nominal Jacket Thickness(Inches) 0.080 |
Nominal O.D (Inches) 1.580 |
Approx Net WT./MFT 2595 |
Conductor Size (AWG) 250 MCM |
Number of Conductors 3 | Ground Size 4 | Nominal Jacket Thickness(Inches) 0.110 |
Nominal O.D (Inches) 1.750 |
Approx Net WT./MFT 3039 |
Conductor Size (AWG) 350 MCM |
Number of Conductors 3 | Ground Size 3 | Nominal Jacket Thickness(Inches) 0.110 |
Nominal O.D (Inches) 2.150 |
Approx Net WT./MFT 3698 |
Conductor Size (AWG) 500 MCM |
Number of Conductors 3 | Ground Size 2 | Nominal Jacket Thickness(Inches) 0.110 |
Nominal O.D (Inches) 2.230 |
Approx Net WT./MFT 5678 |
Customer Support & Order Information
At Alan Wire, we’re proudly committed to serving you. Find the help you need or access your order information by making a selection below.
FREIGHT PRE-PAID
Orders Over 2,000 Pounds
Our low freight pre-paid threshold makes our products more affordable and accessible to everyone, not just the largest of customers.